{"id":287,"date":"2022-08-02T10:38:10","date_gmt":"2022-08-02T08:38:10","guid":{"rendered":"https:\/\/caemi2i.in2p3.fr\/?page_id=287"},"modified":"2022-09-14T16:46:59","modified_gmt":"2022-09-14T14:46:59","slug":"287-2","status":"publish","type":"page","link":"https:\/\/caemi2i.in2p3.fr\/index.php\/287-2\/","title":{"rendered":"Galeries"},"content":{"rendered":"\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Type<\/th><th class=\"column-2\">Laboratoire<\/th><th class=\"column-3\">Nom de l'ASIC \/ contact<\/th><th class=\"column-4\">Caract\u00e9ristiques<\/th><th class=\"column-5\">Photos<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Analogique<\/td><td class=\"column-2\">LPC Caen<\/td><td class=\"column-3\">MCC\u00b2SA (Multi-Channel Configurable Charge Sensitive Amplifier)<br \/>\n<br \/>\nContact : <a href=\"mailto:sdrouet@lpccaen.in2p3.fr\">sdrouet@lpccaen.in2p3.fr<\/a><\/td><td class=\"column-4\">Technology : AMS 0,35\u00b5m CMOS<br \/>\n<br \/>\nDatasheet : <a href=\"https:\/\/caemi2i.in2p3.fr\/index.php\/504-2\/\">MCC2SA.pdf<\/a><br \/>\n<br \/>\nApplication : Nuclear Physics, Si detector<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2022\/09\/mcc2sa-300x171.png\" alt=\"\" width=\"300\" height=\"171\" class=\"alignnone size-medium wp-image-499\" srcset=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2022\/09\/mcc2sa-300x171.png 300w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2022\/09\/mcc2sa.png 432w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Analogique<\/td><td class=\"column-2\">IP2I Lyon<\/td><td class=\"column-3\">LARZIC (Liquid Argon Zygote Intergrated Circuit)  <br \/>\n<br \/>\nContact : <a href=\"mailto:e.bechetoille@ip2i.in2p3.fr\"> Edouard Bechetoille<\/a><\/td><td class=\"column-4\">Technology : AMS 0,35\u00b5m CMOS<br \/>\n1657.6\u00b5m x 3368.6\u00b5m<br \/>\nArea : 5.58 mm\u00b2<br \/>\n<br \/>\nDatasheet : <a> En cours...<\/a><br \/>\n<br \/>\nApplication : Liquid Argon Time Projection Chamber. Dedicated to Neutrino DUNE experiment<\/td><td class=\"column-5\"><img decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/01\/IMG_0469.heic\" alt=\"\" class=\"alignnone size-full wp-image-817\" \/> <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/01\/IMG_0469-300x108.jpg\" alt=\"\" width=\"300\" height=\"108\" class=\"alignnone size-medium wp-image-821\" srcset=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/01\/IMG_0469-300x108.jpg 300w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/01\/IMG_0469-1024x368.jpg 1024w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/01\/IMG_0469-768x276.jpg 768w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/01\/IMG_0469-1536x551.jpg 1536w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/01\/IMG_0469-2048x735.jpg 2048w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Analogique (+mixte busI2C)<\/td><td class=\"column-2\">APC Paris<\/td><td class=\"column-3\">AwaXe_v3 (ATHENA warm ASIC for the X-IFU electronics)<br \/>\n<br \/>\nContact : <a href=\"mailto:sichen@apc.in2p3.fr\"> Si Chen<\/a>, <a href=\"mailto:prele@apc.in2p3.fr\"> Damien Pr\u00eale<\/a><\/td><td class=\"column-4\">Technology : AMS 0,35\u00b5m BiCMOS<br \/>\n<br \/>\nDatasheet : <a href=\" https:\/\/apc.u-paris.fr\/~prele\/datasheet_AwaXe_v3.pdf \">AwaXe_v3.pdf<\/a><br \/>\n<br \/>\nApplication : Control and low-noise readout of superconducting multiplexed detection chain for spaceborne instrument ATHENA X-IFU<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/apc.u-paris.fr\/~prele\/AwaXe_v3.jpg\" alt=\"\" width=\"250\" height=\"200\" class=\"alignnone size-medium wp-image-821\" \/><br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Analogique (+mixte : DACs)<\/td><td class=\"column-2\">APC Paris<\/td><td class=\"column-3\">AwaXe_v4 (intermediate test analog functions for AwaXe in ST)<br \/>\n<br \/>\nContact : <a href=\"mailto:sichen@apc.in2p3.fr\"> Si Chen<\/a>, <a href=\"mailto:mesquida@apc.in2p3.fr\"> Jean Mesquida<\/a>, <a href=\"mailto:prele@apc.in2p3.fr\"> Damien Pr\u00eale<\/a><\/td><td class=\"column-4\">Technology : ST 130 nm BiCMOS<br \/>\n<br \/>\nDatasheet : <a href=\" https:\/\/apc.u-paris.fr\/~prele\/datasheet_AwaXe_v4.pdf \">AwaXe_v4.pdf<\/a><br \/>\n<br \/>\nApplication : Transposition of the LNA and the DAC of the AwaXe_v3 into ST technology, in preparation of the spaceborne instrument ATHENA X-IFU<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/apc.u-paris.fr\/~prele\/AwaXe_v4.bmp\" alt=\"\" width=\"250\" height=\"200\" class=\"alignnone size-medium wp-image-821\" \/><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Analogique<\/td><td class=\"column-2\">APC Paris<\/td><td class=\"column-3\">AwaXe_v4dot5LNA (updated version of the AwaXe_v4 LNA with internal biasing and offset compensation)<br \/>\n<br \/>\nContact : <a href=\"mailto:sichen@apc.in2p3.fr\"> Si Chen<\/a>, <a href=\"mailto:prele@apc.in2p3.fr\"> Damien Pr\u00eale<\/a><\/td><td class=\"column-4\">Technology : ST 130 nm BiCMOS<br \/>\n<br \/>\nDatasheet : <a> ask contacts for internal documentations <\/a><br \/>\n<br \/>\nApplication : SQUID amplification and offset compensation, in preparation of the spaceborne instrument ATHENA X-IFU<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/apc.u-paris.fr\/~prele\/AwaXe_v4dot5LNA.png\" alt=\"\" width=\"250\" height=\"200\" class=\"alignnone size-medium wp-image-821\" \/><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Mixte analogique DAC<\/td><td class=\"column-2\">APC Paris<\/td><td class=\"column-3\">AwaXe_v4dot5DAC (updated version of the AwaXe_v4 DAC with INL<LSB and 10 bits)<br \/>\n<br \/>\nContact : <a href=\"mailto:mesquida@apc.in2p3.fr\"> Jean Mesquida<\/a>, <a href=\"mailto:sichen@apc.in2p3.fr\"> Si Chen<\/a>, <a href=\"mailto:prele@apc.in2p3.fr\"> Damien Pr\u00eale<\/a><\/td><td class=\"column-4\">Technology : ST 130 nm BiCMOS<br \/>\n<br \/>\nDatasheet : <a> ask contacts for internal documentations <\/a><br \/>\n<br \/>\nApplication : SQUID and TES biasing, in preparation of the spaceborne instrument ATHENA X-IFU<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/apc.u-paris.fr\/~prele\/AwaXe_v4dot5DAC.png\" alt=\"\" width=\"250\" height=\"200\" class=\"alignnone size-medium wp-image-821\" \/><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">\"Num\u00e9rique\" <\/td><td class=\"column-2\">APC Paris<\/td><td class=\"column-3\">AwaXe_v5FC (intermediate test digital functions RS4895 and I2C RHBD full custom in ST)<br \/>\n<br \/>\nContact : <a href=\"mailto:sichen@apc.in2p3.fr\"> Si Chen<\/a>, <a href=\"mailto:mesquida@apc.in2p3.fr\"> Jean Mesquida<\/a>, <a href=\"mailto:prele@apc.in2p3.fr\"> Damien Pr\u00eale<\/a>,  <a href=\"mailto:manuel.gonzalez@apc.in2p3.fr\"> Manuel Gonzalez <\/a>, <a href=\"mailto:courtyb@apc.in2p3.fr\"> Bernard Courty <\/a><\/td><td class=\"column-4\">Technology : ST 130 nm BiCMOS<br \/>\n<br \/>\nDatasheet : <a> ask contacts for internal documentations <\/a><br \/>\n<br \/>\nApplication : Transposition of the bus of the AwaXe_v3 into ST technology, in preparation of the spaceborne instrument ATHENA X-IFU<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/apc.u-paris.fr\/~prele\/AwaXe_v5FC.png\" alt=\"\" width=\"250\" height=\"100\" class=\"alignnone size-medium wp-image-821\" \/><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Num\u00e9rique<\/td><td class=\"column-2\">APC Paris \/ Weeroc<\/td><td class=\"column-3\">AwaXe_v5DF (intermediate radhard by design I2C in ST using the digital flow)<br \/>\n<br \/>\nContact : <a href=\"mailto:sichen@apc.in2p3.fr\"> Si Chen<\/a>, <a href=\"mailto:mesquida@apc.in2p3.fr\"> Jean Mesquida<\/a>, <a href=\"mailto:prele@apc.in2p3.fr\"> Damien Pr\u00eale<\/a>,  <a href=\"mailto:manuel.gonzalez@apc.in2p3.fr\"> Manuel Gonzalez <\/a>, <a href=\"mailto:courtyb@apc.in2p3.fr\"> Bernard Courty <\/a>, <a href=\"mailto:julien.fleury@weeroc.com>\"> Julien Fleury<\/a><\/td><td class=\"column-4\">Technology : ST 130 nm CMOS<br \/>\n<br \/>\nDatasheet : <a> ask contacts for internal documentations <\/a><br \/>\n<br \/>\nApplication : Transposition of the bus of the AwaXe_v3 into ST technology using the digital flow, in preparation of the spaceborne instrument ATHENA X-IFU<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/apc.u-paris.fr\/~prele\/AwaXe_v5DF.png\" alt=\"\" width=\"250\" height=\"100\" class=\"alignnone size-medium wp-image-821\" \/><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Analogique<\/td><td class=\"column-2\">\"R&amp;T BiCMOS\" team : APC, IP2I, LPCA, LPC Caen, SUBATECH<\/td><td class=\"column-3\">R&amp;T_SiGe<br \/>\n<br \/>\nContact : <a href=\"mailto:didier.charrier@subatech.in2p3.fr\"> Didier Charrier<\/a><\/td><td class=\"column-4\">Technology : IHP SG13S, 130nm SiGe<br \/>\n<br \/>\nDatasheet : to be done<br \/>\n<br \/>\nApplication : building blocks for the evaluation of the IHP SG13S technology : LNA, TIA, Thermometer, CMOS amplifier, NPN arrays.<br \/>\nNuclear and astroparticle physics<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/RTBiCMOS-300x226.jpg\" alt=\"\" width=\"300\" height=\"226\" class=\"alignnone size-medium wp-image-1204\" srcset=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/RTBiCMOS-300x226.jpg 300w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/RTBiCMOS-1024x771.jpg 1024w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/RTBiCMOS-768x578.jpg 768w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/RTBiCMOS.jpg 1532w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Analogique<\/td><td class=\"column-2\">SUBATECH<\/td><td class=\"column-3\">LONAMOS (LOw Noise Amplifier in MOS technology)<br \/>\n<br \/>\nContact : <a href=\"mailto:didier.charrier@subatech.in2p3.fr\"> Didier Charrier<\/a><\/td><td class=\"column-4\">Technology : AMS C35B4C3, 350nm CMOS<br \/>\n<br \/>\n20MHz features, LNA with 2:1 output BALUN <br \/>\n* NFmin < 1dB in [1-100]MHz<br \/>\n* IIP3 : 1.1V, OIP3 : 33dBm<br \/>\n* BW : 100kHz-200MHz<br \/>\n* Gv : 19.3dB<br \/>\n* Zin : 297ohm \/\/ 6pF, 3 modes<br \/>\n* Max out dyn : 3 Vpp on 50ohm load<br \/>\n<br \/>\nApplication : RF LNA for active antennas.<br \/>\n* Radio detection cosmic rays experiment : CODALEMA\/EXTASIS, TREND\/GRAND<br \/>\n* LF radio astronomy : NenuFAR(SKA)<\/td><td class=\"column-5\"><img decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2024\/09\/layoutlonamoscrop.jpg\" alt=\"\" width=\"250\" class=\"alignnone size-medium wp-image-936\" \/><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Mixte analogique - num\u00e9rique<\/td><td class=\"column-2\">IP2I, IJClab, LP2iB, LPC-caen, LPCA, OMEGA<\/td><td class=\"column-3\">FASTIME : <br \/>\nContact :  Mokrane DAHOUMANE<\/td><td class=\"column-4\">Technologie : TSMC 130nm<br \/>\n4.15 mm x 2.6 mm<br \/>\n4 channel (Front-End + Comparateur + TDC)<\/td><td class=\"column-5\"><img decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2026\/01\/FASTIME_layout.png\" width=\"250\" class=\"alignnone size-medium wp-image-936\" \/><\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Num\u00e9rique<\/td><td class=\"column-2\">IP2I + CERN<\/td><td class=\"column-3\">CIC (Concentrateur Integrated Circuit). <a href=\"https:\/\/www.ip2i.in2p3.fr\/support-a-la-recherche\/electronique\/#cic\">details.<\/a><br \/>\nContact : Luigi Caponetto, Benedetta Nodari<\/td><td class=\"column-4\">Technology : TSMC 65nm<br \/>\n320MHz readout<br \/>\n[1-1.2V] [250-315mW]<br \/>\n2.8mm x 6.5mm<br \/>\nRadTol 200Mrad<\/td><td class=\"column-5\"><img decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2026\/01\/CIC.png\" alt=\"concentrateur\" width=\"250\" class=\"alignnone size-medium wp-image-936\" \/><\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Analogique (+mixte : DACs)<\/td><td class=\"column-2\">APC Paris<\/td><td class=\"column-3\">AwaXe_v6\/EM (ATHENA warm ASIC for the X-IFU electronics) <br \/>\n<br \/>\n2 full channels for ATHENA X-IFU readout<br \/>\n<br \/>\nContact : <a href=\"mailto:sichen@apc.in2p3.fr\"> Si Chen<\/a>, <a href=\"mailto:mesquida@apc.in2p3.fr\"> Jean Mesquida<\/a>, <a href=\"mailto:prele@apc.in2p3.fr\"> Damien Pr\u00eale<\/a><\/td><td class=\"column-4\">Technology : ST 130 nm BiCMOS<br \/>\n<br \/>\n6550 \u03bcm x 2140 \u03bcm<br \/>\n<br \/>\nDatasheet en preparation<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/AwaXe_vEM_Bino-300x113.jpg\" alt=\"\" width=\"300\" height=\"113\" class=\"alignnone size-medium wp-image-1206\" srcset=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/AwaXe_vEM_Bino-300x113.jpg 300w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/AwaXe_vEM_Bino-1024x386.jpg 1024w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/AwaXe_vEM_Bino-768x289.jpg 768w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/AwaXe_vEM_Bino-1536x579.jpg 1536w, https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/06\/AwaXe_vEM_Bino.jpg 2033w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Mixte analogique-num\u00e9rique<\/td><td class=\"column-2\">OMEGA-MiCA<\/td><td class=\"column-3\">ALTIROC<br \/>\n<br \/>\n225 LGAD pixels timing readout chip<br \/>\n<br \/>\nContact : <a href=\"mailto:nsmoreau@in2p3.fr\"> Nathalie Seguin-Moreau<\/a>, <a href=\"mailto:alexandre.soulier@clermont.in2p3.fr\"> Alexandre Soulier<\/a><\/td><td class=\"column-4\">Technology : TSMC 130 nm<br \/>\n<br \/>\n2cm x 2 cm<br \/>\n<br \/>\nDatasheet : <a> ask contacts for internal documentations <\/a><br \/>\n<br \/>\nToA (20ps) and ToT (40ps) TDCs - Luminosity measurements<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/03\/Alti3_WB_photo.jpg\" alt=\"\" width=\"250\" height=\"150\" class=\"alignnone size-medium wp-image-821\" \/><\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Mixte analogique-num\u00e9rique<\/td><td class=\"column-2\">IP2I-IPHC-SHANDONG-NANKAI<\/td><td class=\"column-3\">PICMIC-0<br \/>\n<br \/>\nContact : <a href=\"mailto:e.bechetoille@ip2i.in2p3.fr\"> Edouard Bechetoille<\/a><\/td><td class=\"column-4\">TJ180nm 8.4*8.4mm\u00b2<br \/>\n<a href=\"https:\/\/www.ip2i.in2p3.fr\/support-a-la-recherche\/electronique\/#picmic\">details <\/a><br \/>\n<\/td><td class=\"column-5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/caemi2i.in2p3.fr\/wp-content\/uploads\/2025\/07\/IMG_4598-scaled.jpg\" alt=\"PICMIC-0 in setup\" width=\"250\" height=\"150\" class=\"alignnone size-medium wp-image-821\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache -->\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-287","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/pages\/287","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/comments?post=287"}],"version-history":[{"count":9,"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/pages\/287\/revisions"}],"predecessor-version":[{"id":815,"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/pages\/287\/revisions\/815"}],"wp:attachment":[{"href":"https:\/\/caemi2i.in2p3.fr\/index.php\/wp-json\/wp\/v2\/media?parent=287"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}